7
4) Remove and inspect brass spray jets. If
necessary, clean jets in acetic acid
solution.
NOTE: Do not clean brass jets with a
pointed object, as it will damage the jets.
5) Check brush assembly & remove any
debris or carpet fibers.
6) Check pick up head and remove any
debris or carpet fibers.
7) Check condition of the stainless steel
pickup shoes on the pickup head. The
shoes must contact the floor for the
whole length of the pickup head.
Replace as necessary.
8) Clean machine with a nonabrasive
cleaner.
9) Inspect power cable for any damage.
Replace if necessary.
MONTHLY MAINTENANCE
1) Flush pump & plumbing with an acetic
acid solution to dissolve any chemical
buildup.
Mixing Instructions:
a) Premix 16 oz. or an acetic acid
solution with 2 gallons of water and
pour into solution tank.
b) Turn vacuum / pump switch on
c) Put machine head over floor
drain and operate machine for 50
seconds.
d) Shut machine down and allow
remaining solution to sit in
machine overnight.
e) The following day, spray out
remaining solution and flush
system again with 3 gallons of
clean water.
2) Inspect machine for water leaks.
3) Lubricate wheels with a water resistance
lubricant.
4) Check machine for loose or missing
nuts, screw and bolts and replace as
necessary.
MACHINE STORAGE
1) Prior to storing the machine, ensure the
solution and recovery tanks are clean
and empty of any solution.
2) Store machine in upright position in a
dry area, with the brush head off the
floor.
3) Remove recovery tank clear lid to
allow for air circulation.
NOTE: If you are storing the machine in
an area which can freeze, be sure both
tanks and the solution plumbing are empty
of all water and dry!